
FOTING FT-Q1300215-BLUEFOTING 1.5HP 9000GPH Sewage Pump
1.5 HP, 9000 GPH, 2 in solids and a 3-year warranty.
- Motor horsepower
- 1.50 HP
- Max flow rate
- 9000 GPH
- Solids handling size
- 2.0 in
A sewage ejector pump sits in a sealed basin below a basement bathroom or laundry and lifts waste up to the main sewer line, which runs higher than the fixtures. It must pass solids without clogging, so most residential ejectors handle 2 in solids through a 2 in discharge. A grinder pump goes further, chopping waste with blades so it can push it farther or higher through smaller pipes. Compare lift height against the rise to your sewer line, solids handling, the float switch and the housing. Many areas require a licensed plumber and a vented, sealed basin for these installs. We put 11 sewage ejector pumps on one spec sheet so you can compare them side by side.
Quick answer
Ranked from 11 sewage ejector pumps that met our standard, compared on solids handling size, max head height, horsepower.
As an Amazon Associate I earn from qualifying purchases. Links to retailers on this site are affiliate links; we may earn a commission at no extra cost to you.

1.5 HP, 9000 GPH, 2 in solids and a 3-year warranty.

Cast iron, 6600 GPH and a 3-year warranty.

Stainless blades and 40 ft of lift.
| Spec | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Best Scoreout of 100 | 87 | 75 | 71 | 69 | 66 | 62 | 58 | 48 | 46 | 43 |
| Motor horsepowerHP | 1.50 HP (best in row) | 1.00 HP | 1.00 HP | 1.50 HP (best in row) | 0.75 HP | 0.75 HP | 1.00 HP | 0.40 HP | 0.50 HP | 0.40 HP |
| Max flow rateGPH | 9000 GPH (best in row) | 6600 GPH | 4200 GPH | 6600 GPH | 6400 GPH | 7200 GPH | 5100 GPH | 5995 GPH | 4800 GPH | 5400 GPH |
| Max vertical liftft | 29 ft | 27 ft | 40 ft | 42 ft (best in row) | 29 ft | 32 ft | — | 24 ft | 25 ft | 18 ft |
| Solids handling sizein | 2.0 in | — | 2.0 in | 2.0 in | 2.0 in | 2.0 in | — | 2.0 in | 2.0 in | 2.0 in |
| Discharge sizein | 2.0 in | 2.0 in | 2.0 in | 2.0 in | 2.0 in | 2.0 in | 2.0 in | 2.0 in | 2.0 in | 2.0 in |
| Pump housing material | Cast iron | Cast iron | Cast iron | Stainless steel | Cast iron | Cast iron | Cast iron | Cast iron | Cast iron | Cast iron |
| Float switch type | Tethered float | Tethered float | — | — | Tethered float | — | — | Tethered float | Vertical float (best in row) | — |
| Basin included | — | — | — | — | — | — | Yes | — | Yes | — |
| Thermal overload protection | Yes | Yes | — | Yes | Yes | — | — | Yes | Yes | — |
| Power cord lengthft | 10 ft | 10 ft | — | 30 ft (best in row) | 10 ft | 10 ft | — | — | 10 ft | 10 ft |
| VoltageV | — | — | 220 V | 110 V | 115 V | 115 V | 120 V | — | — | 115 V |
| Weightlb | 34.2 lb | 29.1 lb (best in row) | — | — | — | — | 53.1 lb | 39.6 lb | 50.0 lb | 34.5 lb |
| Warrantyyears | 3 years (best in row) | 3 years (best in row) | 2 years | — | 2 years | — | — | 2 years | 1 year | — |
We reviewed 18 sewage ejector pumps and kept only the 11 that pass every check below. Those are ranked by a Best Score built from spec fit for this job, warranty, sales rank.
These reviews are based on each pump's published specifications and listing information, in the order of our ranking. Flow and lift are maximum figures.
FOTING 1.5 HP with the most flow
The FOTING sewage pump leads our ranking. Its 1.5 HP PSC motor, tied for the most powerful here, moves up to 9,000 gallons per hour, the highest flow on this page, and lifts up to 29 ft, enough for most basement bathrooms below a sewer line.
It has a rugged cast iron casing, a reinforced non-clogging vortex impeller and a 2 in NPT discharge, and it passes solids up to 2 in. An adjustable tethered float switch runs it automatically, and you can also run it manually. Built-in thermal overload protection stops the motor burning out during dry runs or voltage surges, and a mechanical seal helps keep water out of the motor.
It weighs 34.17 lb, has a 10 ft cord and carries a 3-year warranty, tied for the longest here. A tethered float needs a basin wide enough for it to swing freely. For homeowners who want strong, reliable ejection from a basement bathroom, it is the best choice on this page. Install a check valve and a shut-off valve in the discharge line, and keep the basin lid sealed and vented.
VerdictThe best sewage ejector on this page.
LANCHEZ 1 HP cast iron ejector
Second in our ranking, the LANCHEZ sewage pump uses a 1 HP PSC copper motor that LANCHEZ says is energy efficient and quiet. It moves up to 6,600 gallons per hour and lifts up to 27 ft.
The cast iron casing resists corrosion and sheds motor heat into the surrounding water, which helps it cool and last longer under frequent use. An adjustable tethered float switch turns it on as the basin fills and off as it empties, and thermal overload protection guards the motor.
It has a 2 in NPT discharge for high capacity, a 10 ft grounded waterproof cord with a handle, weighs 29.12 lb and carries a 3-year warranty, tied for the longest here. Solids handling is not listed in our data, so confirm it passes 2 in solids if that is required where you live. For homeowners who want a sturdy 1 HP ejector with a long warranty, it is an excellent pick. Use a check valve so waste in the pipe does not drain back into the basin after each cycle.
VerdictA solid, well-backed ejector.
Aquastrong 1 HP grinder on 220V
The Aquastrong SEP100CA ranks third and is a grinder pump rather than a plain ejector. Its stainless steel blades cut through soft and semi-rigid debris such as wipes, twigs and zip ties, which can jam a standard vortex pump.
It runs on 220V single-phase power, the only 220V pump in our top five, which Aquastrong says gives stronger torque and faster start-up. It draws 4.1 amps, which reduces voltage drop and helps prevent overheating. It lifts up to 40 ft, more than the ejectors above, and moves up to 4,200 gallons per hour, the lowest flow here, which is typical for a grinder.
It has a cast iron housing, a 2 in discharge, passes 2 in solids and has an adjustable float switch for automatic or manual use. Aquastrong lists a 2-year warranty. You need a 220V circuit, so plan wiring before buying. For homes where wipes are flushed or the sewer line is high, it is a strong choice. Keep the pump fully submerged when running automatically, as Aquastrong advises.
VerdictThe best 220V grinder here.
Schupethauer 1.5 HP grinder with the most lift
Fourth in our ranking, the Schupethauer grinder pump has a 1.5 HP motor, tied for the most powerful, and lifts up to 42 ft, the highest on this page. It moves up to 6,600 gallons per hour, strong for a grinder.
Its industrial-grade adjustable mechanical float switch runs it automatically when the water rises, and you can run it manually. The housing is corrosion-proof stainless steel on a rugged cast iron base, and automatic thermal overload protection shuts it off if it runs dry or overheats.
A 30 ft cord, the longest here, reaches distant outlets, and it runs on 110V, so it plugs into ordinary household power. It has a 2 in discharge and passes 2 in solids. Our data does not list its weight or warranty. For basements far below the sewer line, or long runs, it offers the most lift. Plug it into a dedicated GFCI-protected circuit, and keep the float clear of the basin wall so it rises and falls freely.
VerdictThe highest-lift pump here.
Acquaer 3/4 HP sewage pump
The Acquaer 3/4 HP sewage pump completes our top five. Its oil-filled split capacitor motor moves up to 6,400 gallons per hour and lifts up to 29 ft, close to the leader's lift with a smaller motor.
An adjustable mechanical tethered float switch turns it on and off automatically in a sump basin or septic pit, and it can also run manually. The rugged cast iron casing, reinforced non-clogging vortex impeller and 2 in discharge pass solids up to 2 in.
Built-in thermal overload protection prevents burnout if it runs dry. It runs on 115V with a 10 ft cord and carries a 2-year warranty. Oil-filled motors run cooler and quieter, which suits a pump that cycles often under a bathroom. For a smaller basement bathroom or laundry with modest lift needs, it is a good value. Size the basin for the fixtures it serves, keep the lid sealed and vented to code, and test the float every few months by running water into the basin.
VerdictA good-value 3/4 HP ejector.
Best among the reviewed tools
Ejectors pass 2 in solids. Grinders chop waste and suit higher lifts or flushed wipes.
Lift must cover the rise to the sewer line. Pumps here lift 18 to 42 ft.
Most run on 110V or 115V. Some grinders need 220V.
Use a sealed, vented basin, a check valve and a shut-off valve. Many areas require a plumber.
A sump pump moves groundwater. An ejector handles waste with solids from toilets and drains.
Only for high lifts, long runs or small pipes. A standard ejector suits most basement bathrooms.
It depends on lift, pipe run and fixtures. Many basement bathrooms use 1/2 to 1 HP.
Yes, in most codes. The sealed basin needs a vent to release gas and allow flow.
Your own selection is kept in the link, so friends see the same side-by-side.