Rogvoc U26VG90NEW1Rogvoc HVAC Micron Vacuum Meter
Lists ±5% accuracy, a 75000 micron range, a target alarm and a backlight.
- Max measuring range
- 75000 microns
- Accuracy (% of reading)
- 5 %
- Adjustable target alarm
- Yes
A good micron gauge for AC work reads low, reads close and tells you the target was reached. Look at accuracy as a percent of reading, sensor type, units and whether the gauge lists temperature compensation. Also check overload pressure and power source. Most gauges here use a Pirani sensor. We put 7 products on one spec sheet and ranked them on those specs. Our reviews cover the top five, based on specifications and listing information.
Quick answer
Ranked from 7 micron vacuum gauges that met our standard, compared on Micron accuracy, measuring range, and temperature compensation.
As an Amazon Associate I earn from qualifying purchases. Links to retailers on this site are affiliate links; we may earn a commission at no extra cost to you.

Lists ±5% accuracy, a 75000 micron range, a target alarm and a backlight.

Matches the top Rogvoc on accuracy, range and alarm, but lists no unit count.

Shows humidity and evaporation temperature, with 1 micron resolution up to 1,000 microns.
| Spec | |||||||
|---|---|---|---|---|---|---|---|
| Best Scoreout of 100 | 75 | 69 | 66 | 65 | 58 | 51 | 29 |
| Max measuring rangemicrons | 75000 microns (best in row) | 75000 microns (best in row) | 75000 microns (best in row) | — | 75000 microns (best in row) | 75000 microns (best in row) | 5000 microns |
| Accuracy (% of reading)% | 5 % (best in row) | 5 % (best in row) | — | 10 % | 10 % | 10 % | — |
| Sensor type | Thermal conductivity / Pirani | Thermal conductivity / Pirani | Thermal conductivity / Pirani | Thermal conductivity / Pirani | Thermal conductivity / Pirani | Thermal conductivity / Pirani | Thermal conductivity / Pirani |
| Selectable unitsunits | 4 units | — | 9 units | 4 units | 11 units (best in row) | — | 1 units |
| Adjustable target alarm | Yes | Yes | Yes | — | Yes | Yes | — |
| Backlit display | Yes | Yes | Yes | — | Yes | Yes | — |
| Auto shut-off | — | — | — | Yes | — | — | — |
| Temperature compensation | — | — | — | Yes | — | — | — |
| Max overload pressurepsi | 72 psi | 72 psi | 29 psi | 600 psi (best in row) | — | 29 psi | 500 psi |
| Port connection | 7/16-20 UNF (1/4 in SAE), tee connector | 7/16-20 UNF (1/4 in SAE), tee connector | 1/4" SAE interface | 1/4in female SAE refrigerant hose type | 1/4" SAE fitting, T-connector | 1/4" SAE (7/16-20 UNF) | 1/4" SAE flare fitting |
| Power source | 3 AA batteries | 3 AA batteries | 3x AA batteries | One 9 volt alkaline battery | 3x AA batteries (included) | 3x AA batteries (not included) | 9 V battery (not included) |
| Weightlb | — | — | 0.78 lb | 0.34 lb (best in row) | 0.78 lb | — | 0.66 lb |
| Carrying case included | Yes | Yes | — | Yes | Yes | Yes | — |
We reviewed 14 micron vacuum gauges and kept only the 7 that pass every check below. Those are ranked by a Best Score built from spec fit for this job, sales rank.
These reviews cover the five top-ranked gauges. They are based on specifications and listing information.
Rogvoc U26VG90NEW1 leads on accuracy and alarm features
A deep evacuation check needs a gauge that reads low and reads close. The Rogvoc U26VG90NEW1 lists accuracy of ±5%, the lowest figure on this page, shared with the other Rogvoc. Its Pirani thermal conductivity sensor reads up to 75,000 microns, so it follows the pump from high pressure down to the low range.
It reads in Pa, mBar, mmHg and microns, so you can stay in microns for AC work. A target alarm lets you set a vacuum level. When the system reaches it, the screen flashes and the buzzer sounds. The alarm stops on any key press or after 35 seconds. The maker lists a large backlit LCD for dark spaces.
One gap matters for this keyword. The maker does not publish temperature compensation, so check that before you rely on it in a hot garage. It lists a working temperature of -23℉–122℉ and an overload limit of 72 psi. The kit adds a tee connector, a tool bag and 3 AA batteries.
VerdictIt leads our ranking and fits deep evacuation checks well, apart from the missing temperature compensation.
Rogvoc RV-VG200-26 offers the same sensor at second rank
This model shares its core specs with the top-ranked Rogvoc: a Pirani sensor, a 75,000 micron maximum range and ±5% accuracy. That range covers the whole job, from air at the start to deep vacuum at the end. Our spec sheet has no entry for its selectable units, which is a likely reason it ranks second. The listing text still names four units, including microns.
For evacuation work, the alarm is the useful extra. You set a target vacuum with the SET button. Once the system hits it, the screen flashes and a buzzer sounds. Any key silences it, or it stops after 35 seconds. A backlit LCD helps in dim spaces, and the case is a tool bag.
Like its sibling, it does not list temperature compensation, so it only partly fits a buyer who wants it. It lists a 72 psi overload limit and a 7/16-20 UNF (1/4 in SAE) connection with a tee connector. Power comes from 3 AA batteries.
VerdictA capable twin of the top pick that needs the same caution on temperature.
Vanlison MOG2034 adds humidity and boiling point readouts
The Vanlison MOG2034 reads from 0 to 75,000 microns with a Pirani sensor. The listing gives a resolution as fine as 1 micron in the 0 to 1,000 micron range. That fine step helps when you judge a deep vacuum near the target. The maker does not publish an accuracy percentage.
It also shows ambient humidity (0 to 100% RH) and the evaporation temperature of moisture at the current vacuum. That second reading tells you how well the system is drying out. You can set a target level, and the backlight changes color when the system reaches it. Nine selectable units are listed.
Build details are modest. It weighs 0.78 lb, tied for the heaviest among the models that list it, and runs on 3x AA batteries. The overload rating is 29 psi, tied for the lowest among the models that list it, so keep the port away from pressure. It has a 1/4" SAE port. Temperature compensation is not listed.
VerdictA feature-rich gauge for dehydration checks, held back by missing accuracy and compensation data.
CPS VG200 lists automatic temperature compensation
Temperature compensation is the main reason to look at the CPS VG200. The listing says the gauge adjusts for changing temperature on its own, with no manual steps. That keeps readings steady between a cold shop and a hot driveway. The listing also says it is calibrated to NIST standards.
The weak spots are range and accuracy. The maker does not publish a maximum range in microns. Accuracy is 10% of reading, which ties for the loosest figure among the models that list it. It also has no backlight or target alarm listed, so you must watch the 5-digit LCD yourself.
It is the lightest at 0.34375 lb among the models that list it, and runs on one 9 volt alkaline battery. Auto shut-off helps save that battery. Overload pressure is 600 psi, the highest on the page. The 1/4in female SAE port fits refrigerant hoses, and a padded vinyl case, T-fitting and gauge hook are included.
VerdictIt suits buyers who want compensation and a light, durable unit, but it leaves range and accuracy questions open.
VIVANTECH VA117 offers 11 selectable units and alerts
No other model on this page lists as many selectable units as the VIVANTECH VA117. It offers 11, including microns, mTorr, Torr, Pa and kPa. For AC work you will mostly stay in microns. The extra units help if you compare against pump specs in another scale.
Accuracy is listed as ±(10% rdg + 10 μm) across a 75,000 micron range. That is looser than the ±5% on the two Rogvoc gauges. A preset target changes the screen color and sounds a buzzer, which helps prevent over-evacuation. The backlit display also shows ambient humidity and saturation temperature. The anti-burst sensor design is meant to shield against accidental positive pressure spikes.
The spec sheet has no overload pressure for this model, and temperature compensation is not listed. It weighs 0.78 lb, matching the Vanlison at the heavy end among the models that list weight. The CPS VG200 is lighter, at 0.34375 lb. The kit includes a 1/4" SAE fitting, a T-connector, a tool bag and 3x AA batteries, plus a 1-year warranty.
VerdictA flexible gauge with useful alerts, but accuracy and compensation trail the leaders.
Best among the reviewed tools
Accuracy is given as a percent of reading. Lower is better. Two Rogvoc gauges list ±5%. The CPS, VIVANTECH and Clyiesk models list 10%. A tighter figure means the number on screen is closer to the true vacuum, which matters when you confirm a deep evacuation near the target.
Vacuum sensors can read differently as ambient temperature changes. Compensation corrects for that. Among the products on this page, only the CPS VG200 lists it. If you work in a garage that swings from cold to hot, that line on the spec sheet deserves weight.
A 75,000 micron maximum range lets the gauge show the early pull-down, not just the final low reading. The Supco VG60 tops out at 5,000 microns, so it shows less of the early stage. The CPS VG200 does not publish a maximum range.
A target alarm saves you from watching the screen. The Rogvoc, VANLISON, VIVANTECH and Clyiesk gauges list one. Also check overload pressure. The CPS VG200 lists 600 psi, while the Vanlison and Clyiesk list 29 psi. A higher rating gives more room for mistakes.
The target comes from the system or equipment maker, so follow their service instructions. The gauge's job is to show the level in microns clearly. Models with a target alarm, such as the Rogvoc and VIVANTECH units, can signal when your preset level is reached.
Among the products on this page, only the CPS VG200 lists automatic temperature compensation. The other gauges do not state it in their data. If it matters to you, the CPS is the one to consider, though it does not publish a maximum range or list a backlight.
Yes. Micron units are what you need to confirm a deep evacuation. The Rogvoc gauges and the CPS VG200 each list four units including microns. The VIVANTECH VA117 lists 11 units, with microns among them. The Supco VG60 lists one unit.
It is a weaker fit. It reads only up to 5,000 microns, lists one unit and has no listed alarm, backlight or temperature compensation. It does list a 500 psi overload rating and a 1/4" SAE flare fitting. It ranks seventh on our spec score.